Specifications
  • model

  • VH6-45P5-B
  • product drawing

  • Basic specifications

  • Input power supply

  • Power (kW)

  • Output current (A)

  • Dimension (Width * Height * Depth)

  • Weight (kg)

  • Function

  • Closed loop vector

  • Open loop vector/VF

  • Maximum output frequency

  • Asynchronous motor

  • Synchronous motor

  • Instantly stop without stopping

  • Speed tracking

  • Droop control

  • Position control

  • Brake function

  • Performance

  • Steady speed accuracy

  • Torque control accuracy

  • Start torque

  • Overload capacity

  • Interface Configuration

  • Digital input channels

  • High speed pulse input (50KHz)

  • Analog input channels

  • Digital output channels

  • High speed pulse output (50KHz)

  • Analog output channels

  • ±24V output

  • ±10V output

  • Communication type

  • 485 communication

  • EtherCAT

  • CANopen

  • Encoder type

  • Incremental encoder

  • I/O expansion card

  • I/O expansion card

  • Certificate

  • Certificate

  • Reliability and installation environment requirements

  • IP level

  • Humidity

  • Altitude

  • Maintainability

  • Installation method

  • Terminals pluggable

  • Other optional accessories

  • DC Reactor

  • The original panel supports extension installation

  • Optional panel supports extension installation

  • Braking unit

  • Braking resistor resistance value (Ω)

  • Braking resistor power (W)

  • Three phase AC 320V~440V

  • 5.5

  • 13.0

  • 110*305*202

  • 4.31

  • 1000Hz (VF) ;
    600Hz (Open loop vector/Closed loop vector)

  • FVC:±0.2%;
    SVC:±0.5%;
    VF:±1%

  • FVC:±5% rated torque;
    SVC:±10% rated torque

  • FVC:0Hz 180%;
    SVC:0.5Hz 150%;
    VF:1Hz 150%

  • 150% rated current 60S;
    180% rated current 3S

  • 4 channels (X1-X4), can be expanded 3 more channels (X5-X7) through I/O cards

  • X4

  • 2 (AI1/AI2 supports 0-10V or 0-20mA inputs) , can be extended 1 more channel by an I/O card (AI3 supports -10V to 10V inputs, can be used as PT100 input)

  • 1 channel (Y1) +1 channel (normally ON, normally OFF) , can be extended 1 channel (Y2) +1 channel (normally ON, normally OFF) through I/O card

  • Y2

  • 1, can be expanded 1 more channel through an I/O card

  • VH6-CC100

  • VH6-CN100

  • VH6-DM200

  • Standard VH6-A100, optional VH6-B100

  • CE

  • IP20

  • Less than 95% RH (No condensation)

  • Less than 1000m (When it is higher than 1000m,the output current needs to be reduced by about 10%of therated current for each increase of 1000m)

  • Wall mounted and embedded

  • ×

  • Built-in

  • ≥100

  • ≥1200